Control Logic for Direct Control (Mode=0)

<< Click to Display Table of Contents >>

Navigation:  DeltaShowControlInterface >

Control Logic for Direct Control (Mode=0)

DeltaShowControlInterface has a configuration xml file:

C:\7thSense\Software & Drivers\Delta\Utilities\DeltaShowControlInterface.xml

which features a Mode switch. When set to Mode=0, it will use Delta load, loop, and stop timeline commands. When set to Mode=1, it will trigger Delta sequences. For clarity, the connection for the DeltaShowControlInterface server (or PC) is shown in green, the Delta server (playback) in orange, and the mode is in red. The Shows section is populated when DeltaShowControlInterface show names are added.

<?xml version="1.0" encoding="ISO-8859-1"?>

<DELTA_SHOWCONTROL_INTERFACE_CONFIG>

<COMMENT>Copyright(c) 2010 - 7thSense Design Ltd.  :  DeltaShowControlInterface</COMMENT>

<DATE>28.11.2018  17:8:12</DATE>

<VERSION>3516868</VERSION>

<WINDOW>

<MinimiseOnStart>0</MinimiseOnStart>

</WINDOW>

<DIGITAL_INPUT>

<MyIP>10.100.101.174</MyIP>

<AdamPort>5168</AdamPort>

</DIGITAL_INPUT>

<DELTA_ETHERNET>

<IP>10.100.101.174</IP>

<Port>23</Port>

</DELTA_ETHERNET>

<DELTA_SHOWS>

<Shows>Show1

Show2

Show3

Show4

Show5

Show6

Show7

Show8

</Shows>

</DELTA_SHOWS>

<MODE_OF_OPERATION>

<Mode>0</Mode>

</MODE_OF_OPERATION>

</DELTA_SHOWCONTROL_INTERFACE_CONFIG>

Mode=0, Direct Show Control

The software control is configured using the logic table (DI = digital inputs) below:

DI 0 (pulsed)

= load show

DI 1 (pulsed)

= stop show

DI 2 (on)

= loop show

DI 3-5 (on)

= show selection

Note: P = Pulsed

Which show (up to 8) is addressed depends on the binary array of DI 3 to DI 5:

Input no.

DI 0

DI 1

DI 2

DI 3

DI 4

DI 5

Stop Show

 

P

 

 

 

 

Loop Show

 

 

On

 

 

 

Load Show 1

P

 

 

 

 

 

Load Show 2

P

 

 

On

 

 

Load Show 3

P

 

 

 

On

 

Load Show 4

P

 

 

On

On

 

Load Show 5

P

 

 

 

 

On

Load Show 6

P

 

 

On

 

On

Load Show 7

P

 

 

 

On

On

Load Show 8

P

 

 

On

On

On

Enabling the show to listen to show control

To use this mode requires adding a ‘Stop’ and a ‘Loop’ Control resource to each show that is to be controlled: