Juggler 2 is intended for use in a commercial (not domestic) environment and should be operated in a clean, dust free area (e.g. a server room).

It is intended for operation in benign environments (not subject to corrosive or explosive atmospheres, moisture or flammable gases).

Units are not protected against ingress of liquid (IPx0) or designed to be subject to excessive mechanical shock or vibration.

altitude_2000m_cn-sm

Only used at altitude not exceeding 2000 m

for_not-tropical_regions_cn-sm

Only used in not-tropical climate regions

Thermal

Do not block any of the unit’s air vents and ensure the ambient temperature around the Juggler 2 is compatible with the environmental characteristics stated in the Physical Specifications.

Particularly when mounted in a rack cabinet with front or rear doors the ambient temperature around the unit may be higher than the ambient room temperature.

Electrical

Before connecting power to the unit, ensure the electricity supply is compatible with the electrical ratings shown in this document and on the unit’s product label. The unit shall not be connected to an IT (unearthed neutral) power distribution system and the mains socket-outlet used shall connect to the building installation ground.

Juggler 2 is connected to and disconnected from the mains supply with the IEC 60320 power connector on the rear of the unit.