Name: | Barco LCD VP |
Version: | 6.7.2 |
Available for: | Manager V7 and Manager V6 (Lite & Pro), Showmaster (Mini, ST, Pro, LE, XS & iPro) |
Limitation In: | |
Device Brand: | Barco |
Positrack Compatible: | No |
Resources type: | Serial |
The BARCO LCDMxM provide an easy way to control one or several BARCO LCD video projectors, from your PC’s RS 232 Com port. Several Barco projectors can be controlled independantly from one PC com port, using different adresses on each videoprojector. Adress can be set from 00 to 255 (see barco video projector instructions).
Regular RS 232 cable can be used (DB9 female on PC to DB9 Male on Barco, Barco ref R9827560) Those MxM CommandSet, and VariableSet, are allmust similar to those present in MxM BARCO CRT. A MxM BARCO CRT DEMO Project is downloadable on our Site
No special installation required.
COM Port: choose the PC communication port that will control the BARCO projector
Address: choose the address of the projector to control. The projector address can usually be configured with dip-switches or with onscreen menu settings.
Baud rate: choose the communication baud rate between the PC and the projector. The projector baud rate can usually be configured with dip-switches or with onscreen menu settings.
IQ Series Projector: Indicate if the device is an IQ Series device like IQ300/IQ400.
Turn on or off the projector
Turn on or off the text display mode
Usage: the TextDisplay variable switches between “On” to “Off” depending on the current projector text display mode
Mute on or off the projector
Usage: the Mute variable switches between “On” to “Off” depending on the current projector mute status
Freeze on or off the video
Usage: the Freeze variable switches between “On” to - “Off” depending on the current projector freeze status
Select a video source
Usage: the Source variable is updated with the current selected video source. Brighness, Contrast, Saturation, etc. are saved in the projector memory as source characteristics: thus changing the source will affect the Brighness, Contrast, Saturation, etc. values.
Adjust the brightness value of the current source - Value: [Integer] brightness value, values from 0 to 255
Usage: the Brightness variable is updated with the current selected video source brightness
Adjust the contrast value of the current source - Value: [Integer] contrast value, values from 0 to 255
Usage: the Contrast variable is updated with the current selected video source contrast
Adjust the phase value of the current source
Usage: the Phase variable is updated with the current selected video source phase
Adjust the sharpness value of the current source - Value: [Integer] sharpness value, values from 0 to 3
Usage: the Sharpness variable is updated with the current selected video source sharpness
Adjust the volume value of the current source
Usage: the Volume variable is updated with the current selected video source volume
Adjust the balance value of the current source
Usage: the Balance variable is updated with the current selected video source balance
Adjust the bass value of the current source
Usage: the Bass variable is updated with the current selected video source bass
Adjust the treble value of the current source
Usage: the Treble variable is updated with the current selected video source treble
To open or close the mechanical shutter of the projector
Usage: call this function to open or close the mechanical shutter of the projector.
To shift the lens in the given direction and the given speed
Usage: this function makes a one step move of the lens in the desired direction, you will have to call it several times to reach a given point.
To zoom in or out
Usage: this function makes a one step zoom of the lens in the desired direction, you will have to call it several times to zoom to a given point.
To focus in or out
Usage: this function makes a one step focus of the lens in the desired direction, you will have to call it several times to focus to a given point.
[Enum] monitoring variable for the projector connection status
Usage: use this variable to monitor the projector/PC serial communication
[Integer] monitoring variable for the current selected source
Usage: this variable may change either when calling the SelectSource command or changing the source with the IR-remote.
[Enum] monitoring variable for the text display mode
Usage: this variable may change either when calling the TextDisplay command or changing the text mode with the IR-remote.
[Enum] monitoring variable for the freeze status
Usage: this variable may change either when calling the Freeze command or pressing the freeze button with the IR-remote.
[Enum] monitoring variable for the mute status
Usage: this variable may change either when calling the Mute command or pressing the mute button with the IR-remote.
[Integer] monitoring variable for the brightness value
Usage: this variable may change either when calling the Brightness command or changing the brightness value with the IR-remote.
[Integer] monitoring variable for the contrast value
Usage: this variable may change either when calling the Contrast command or changing the contrast value with the IR-remote.
[Integer] monitoring variable for the phase value
Usage: this variable may change either when calling the Phase command or changing the phase value with the IR-remote.
[Integer] monitoring variable for the sharpness value
Usage: this variable may change either when calling the Sharpness command or changing the sharpness value with the IR-remote.
[Integer] monitoring variable for the voulme value
Usage: this variable may change either when calling the Volume command or changing the volume value with the IR-remote.
[Integer] monitoring variable for the balance value
Usage: this variable may change either when calling the Balance command or changing the balance value with the IR-remote.
[Integer] monitoring variable for the bass value
Usage: this variable may change either when calling the Bass command or changing the bass value with the IR-remote.
[Integer] monitoring variable for the treble value
Usage: this variable may change either when calling the Treble command or changing the treble value with the IR-remote.
[Enum] monitoring variable for the shutter current position
Usage: this variable may change either when calling the Shutter command or pressing the shutter button with the IR-remote.