Name: | Analog Way Graphic Switcher |
Version: | 6.7.2 |
Available for: | Manager V7 and Manager V6 (Lite & Pro), Showmaster (Mini, ST, Pro, LE, XS & iPro) |
Limitation In: | |
Device Brand: | Analog Way |
Positrack Compatible: | No |
Resources type: | Serial |
This MxM provides serial remote control to the Analog Way Graphic Switcher device.
The seamless GRAPHIC SWITCHER II inserts (PIP), cuts, fades, wipes and instantaneously mixes (no glitch) between 16 high-resolution and TV/Video sources which can range from 15 KHz to 130 KHz (Auto Sync & Auto Scan ), up to 1600x1280, with no synchronization “dropouts”. (See http://www.analogway.com for more details).
No special installation is required. The MxM uses the Analog Way serial protocol.
The serial communication port is defined at the top of the window.
On the top is the list of parameters that the device will export.
When the name of a parameter is checked, a corresponding Manager variable is created. This variable can be an Integer or an Enum, depending on the type of the checked parameter.
Note: M is for MAIN, P is for PREVIEW.
The MxM contains all the commands of the protocol. As there is a great number of commands, they have been divided into ten groups, like in the documentation of the protocol. In each command group, the first parameter is an Enum that contains a list of all the contained commands.
A wizzard is available to select the value.
By clicking on it, you open a windows containing the list of parameters available for the command selected in the first parameter. Depending on this command, the window is either a list of values…
… or a window where you can enter an integer value.
By using this wizzard, the value of the parameter selected cannot exceed the min and max values.
The eleventh command id a “read” command, in complement to the Variables mechanism (see Variables section).
Front panel command.
Input command command.
Output command.
Image command.
Effects command.
Sequence mode commands.
Tally outputs commands.
Control and other command.
Note: In the protocol, you can find “Controls commands”, and “Other commands”. Because there is only three “write” commands in the “Other commands”, these commands are grouped here under the “Control and other commands” name.
The other commands, which are “read” commands (like “status commands”, can be accessed through the variable mechanism (see Variables section).
Video output command.
Add-on–1 command.
Read the value of a parameter, in case this parameter is not exported (see Variables section).
Note: This command does not poll the device for the value because all the values of the parameters are maintained internally by the MxM as the hardware device updates them each time they change.
[Enum] Current status of the device.
[Enum or Integer]
Each parameter checked in the setup window has a corresponding variable called DeviceName.ParameterName Note: At each startup of the device, the MxM polls all the values of the parameters, even those which are not checked. The parameters are updated each time they change.